Goodman Furnace Blower Won't Shut Off: Causes & Fixes

Last updated Sep 27, 2026 · By fixme.vip Editorial

Goodman Furnace: Blower won't shut off
Applies to: Most Goodman gas furnaces (GMS, GMV, GMVC, GMEC, GCES/GCVC series) with integrated ignition control boards; fan-timing behavior varies by board revision and by dip-switch or thermostat fan settings.
Typical repair cost: $0 DIY – $1,800 if the blower motor or integrated control board needs replacement

Parts & tools for this fix

As an Amazon Associate, fixme.vip earns from qualifying purchases. Prices and availability are on Amazon.

Goodman furnace blower won't shut off: what it means

“Blower won’t shut off” is not a flash code on your Goodman control board — it’s a symptom. Your indoor blower motor keeps running even when the furnace isn’t heating. On Goodman furnaces, the blower is supposed to run during a heat call, keep running for a set fan-off delay (typically 60–180 seconds, adjustable by dip switch on many boards), then stop.

When it never stops, one of three things is happening: the thermostat is telling the blower to run continuously, a safety switch is forcing the blower to run to cool the cabinet, or the control board/relay has failed in a way that keeps the blower circuit energized. There is no lockout involved here — the furnace isn’t shutting itself down, so there’s usually nothing to reset. The key first question is whether the air is cool/room-temperature (usually a fan setting or relay issue) or hot (usually an open/tripped high-limit).

Repeated high-limit trips with very hot supply air are not a nuisance fault — they mean the furnace is genuinely overheating, and on older furnaces sustained overheating can be a sign of heat-exchanger damage. If that’s what you’re seeing, shut the furnace off at the switch and leave it off until a technician has inspected it, rather than running it while you wait.

Goodman furnace blower won't shut off: common causes, ranked by probability

  1. Thermostat fan set to ON, not AUTO. By far the most common cause. On ON, the blower runs 24/7 by design. This is a setting, not a fault.
  2. Continuous/circulate fan mode enabled. Some thermostats have a “circulate” or programmed continuous-fan schedule that runs the blower most of the time.
  3. Open (tripped) high-limit switch. If the furnace overheats (often from a dirty filter or blocked airflow), the high-limit opens and Goodman boards run the blower continuously to cool the heat exchanger. Here the air is usually hot at first, then room-temp. (A limit that has failed welded closed is a different and more dangerous failure — it no longer protects the furnace at all, and it’s strictly technician territory.)
  4. Failed blower relay on the integrated control board. The relay contacts weld shut, keeping the blower energized regardless of the thermostat. The board may otherwise work fine.
  5. Faulty control board / stuck fan-on timer. A board fault can hold the blower circuit closed or never time out the fan-off delay.
  6. Thermostat wiring fault (stuck G circuit). A shorted or pinched wire keeping the “G” (fan) terminal energized will run the blower nonstop.

How to fix Goodman furnace blower won't shut off: safe checks first

These are safe for any homeowner — no cabinet needs to be opened.

If the supply air is very hot and the high-limit keeps tripping even after a filter change, don’t keep cycling the furnace to “get through the night” — leave it off at the switch and book a technician. If you smell burning, hot metal, or gas, shut the furnace off at the switch; if the odor is gas, get out of the house and call your gas utility or 911 from outside instead of investigating.

If the blower still won’t stop on AUTO with a clean filter and open vents, the fault is inside the cabinet — that’s technician work.

How a technician will diagnose it

A tech will confirm the symptom and narrow it down in roughly this order:

Ask the tech to show you whether the limit is tripping or the board relay is stuck — that determines the repair and the price.

Symptom, cause and what to do

SymptomLikely causeDIY actionTechnician job
Blower runs constantly, air is room-tempFan set to ON or circulate modeSet thermostat to AUTO; disable circulate scheduleCheck G wiring if AUTO doesn’t fix it
Blower runs nonstop even on AUTOStuck blower relay or bad boardCycle breaker once; if it returns, call a proTest board relay; replace control board
Air is hot, blower never stops, filter dirtyOpen/tripped high-limit from overheatingReplace filter; open all vents/registers; if it recurs, shut the furnace off and wait for serviceTest high-limit, clean/repair airflow issue
Blower short-cycles then runs onFaulty fan-off timer on boardNoneCheck dip switches and control board
Blower runs erratically, thermostat glitchyWeak thermostat batteries/wiringReplace batteriesInspect thermostat wiring, replace if faulty

Goodman furnace blower won't shut off repair cost

FixTypical US cost
Thermostat set to AUTO / disable circulate$0 (DIY)
New air filter$10 – $40
Thermostat batteries$5 – $15
New thermostat (if faulty)$25 – $60 DIY part; $150 – $400 installed
High-limit switch replacement$150 – $300
Blower run capacitor replacement$150 – $300
Blower motor replacement (PSC)$450 – $1,800
Blower motor replacement (ECM / variable-speed, e.g. GMV, GMVC, GMEC, GCVC)$800 – $1,500+ installed
Integrated control board replacement$400 – $1,200

A note on the blower relay: on Goodman integrated ignition controls the blower relay is mounted on the board and is generally not serviced on its own. Relay-only repair is uncommon, so the standard fix for a welded relay is replacing the integrated control board — budget for the board price above rather than expecting a cheaper relay swap.

Most “blower won’t shut off” calls turn out to be the fan set to ON — a $0 fix. If it’s inside the cabinet, expect a diagnostic fee ($80–$150) plus parts and labor. Get the tech to identify whether it’s the limit, the board, or the blower motor before authorizing a board swap.

Safety first: anything beyond filters, batteries, and visual checks on gas-burning equipment should be handled by a licensed technician. Repeatedly resetting a locked-out unit can mask a dangerous fault. When in doubt, get a pro.

Rather not DIY it?

Free, no-obligation quotes from licensed HVAC technicians in your area. Compare up to 3 estimates before anyone visits.

Get free local quotes

Frequently asked questions

Why does my Goodman furnace blower run constantly?

The most common reason is the thermostat fan switch set to ON instead of AUTO. Other causes include an open (tripped) high-limit switch holding the blower on to cool the cabinet, a failed blower relay on the control board, or a shorted control board.

Is it safe to keep running the furnace while the blower won't shut off?

If the air coming out is room-temperature or cool and there is no burning smell, it is generally safe short term. If the air is very hot and the blower never stops, shut the furnace off at the switch and call a technician, since that points to an open (tripped) high-limit and an overheating furnace. If you smell burning, hot metal, or gas, shut the furnace off at the switch; if the odor is gas, leave the house first and then call your gas utility or 911 from outside — do not troubleshoot.

Will setting the thermostat fan to AUTO fix it?

Often yes. If the fan was on ON, switching to AUTO lets the blower stop after each heat cycle. If it still runs nonstop on AUTO, the problem is inside the furnace and needs a technician.

Different code on your furnace? Look it up — and if we haven't covered it yet, telling us is how it gets written next.