Rheem Furnace Clicking But Not Starting: Causes & Fixes

Last updated Oct 3, 2026 · By fixme.vip Editorial

Rheem Furnace: Clicking but not starting
Applies to: Most Rheem gas furnaces with hot-surface ignition, including Classic, Classic Plus, Prestige and R801/R802/R95/R96/R97 series. Exact click source and fault codes vary by integrated furnace control board.
Typical repair cost: $0 DIY – $1,200+ if the control board, inducer motor or gas valve needs replacement — compare free local quotes

Get this fixed by a local pro

Free, no-obligation quotes from licensed HVAC technicians in your area. Compare up to 3 estimates before anyone visits.

Get free local quotes

Rheem furnace clicking but not starting: what it means

“Clicking but not starting” isn’t a numbered fault code — it’s a symptom. On a Rheem gas furnace you hear a repeated click (often from the integrated furnace control board relay or the gas valve) but the burners never light and the furnace won’t run a full heat cycle.

The click is usually the control board energizing a relay or the gas valve as it tries to begin the ignition sequence. When ignition or flame proving fails, the board stops, pauses, and tries again — producing that characteristic repeated clicking. After a set number of failed attempts, the board goes into a lockout and flashes a diagnostic code on its status LED.

On most Rheem upflow furnaces, the control board sits in the blower compartment, so you view the LED through the small window in the lower (blower) door, not the burner compartment. Leave the door in place while you look: removing it opens the door-interlock switch, cuts power to the board, and clears the code you’re trying to read. Rheem and Ruud integrated furnace controls typically report faults as a count of flashes, but what each count means varies by board, so match what you see to the code chart for your specific control.

Because the gas valve and ignition system are involved, this is a pro-level repair once the simple homeowner checks are done.

Rheem furnace clicking but not starting: common causes, ranked by probability

This ranking assumes the burners never light at all. If the burners light and then shut off within a few seconds, a flame sensor problem is at least as likely as igniter failure and is often the first thing to suspect.

  1. Failing or dirty hot-surface igniter — the board calls for heat and clicks, but a cracked or worn igniter won’t reach ignition temperature, so burners never light.
  2. Control board relay fault — a worn relay on the integrated furnace control (IFC) clicks but doesn’t reliably pass power to the igniter or inducer.
  3. Failed draft inducer motor or inducer relay — the inducer relay clicks, but the inducer motor doesn’t start or doesn’t come up to speed. The pressure switch never closes, so the board won’t continue to ignition.
  4. Flame sensor fault — burners may light briefly, then the board shuts the valve and re-clicks because it can’t prove flame (overlaps with Flame Sensor Problems).
  5. Open or intermittent safety switch — a tripped limit switch, rollout switch, or pressure switch stops the sequence; the board clicks trying to restart.
  6. Weak low-voltage transformer — a failing 24V transformer can’t hold relays or the gas valve open, causing repeated clicking and dropout.
  7. Gas valve not opening — the valve solenoid clicks (energizes) but fails to open, so no gas reaches the burners.
  8. Loose or corroded low-voltage wiring / connectors — intermittent connections cause the board to cycle and click.

After repeated failed attempts, Rheem IFC boards go into lockout, but lockout behavior and duration vary by control board. Many boards use a timed soft lockout that automatically retries after about an hour. A furnace that keeps locking out has a fault that a technician needs to find; resetting it won’t fix the cause. Watch the flashing fault light to pin down the specific fault — see Rheem Furnace Flashing Light and Rheem Furnace Ignition Lockout for code meanings.

How to fix Rheem furnace clicking but not starting: safe checks first

These are the only steps a homeowner should do:

If the clicking continues after these checks, stop and call a licensed HVAC technician.

How a technician will diagnose it

A technician will:

This sequence lets you sanity-check a quote — a good tech confirms the actual failed component rather than replacing the board blindly.

Symptom, cause and what to do

SymptomLikely causeDIY actionTechnician job
Rapid clicking, no glow, no burner lightFailing igniter or board relayReplace filter; try one resetTest igniter and board relay; replace faulty part
Clicks, burners light briefly, then shut off and re-clickFlame sensor faultNone inside cabinetClean or replace flame sensor; verify microamps
Clicking, inducer won’t start or stopsFailed inducer motor or inducer relay; pressure switch / safety openCheck condensate line and ventsTest inducer motor and relay output; test pressure and limit switches; clear blockage
Click but gas valve never opensGas valve solenoid failureNoneVerify valve operation and gas pressure; replace valve
Clicking with flickering relay sound, drops outWeak transformerTry one resetTest 24V transformer under load; replace
Intermittent clicking, random no-startsLoose/corroded low-voltage wiringConfirm panel is seatedInspect and repair connectors and wiring

Rheem furnace clicking but not starting repair cost

Honest US ranges, parts and labor included:

Prices vary by region and model. Older, variable-speed, or high-efficiency components generally cost more.

Rheem Furnace Won’t Ignite, Rheem Furnace Ignition Lockout, Rheem Furnace Flame Sensor Problems, Rheem Furnace Keeps Shutting Off, Rheem Furnace Short Cycling, Rheem Furnace Won’t Turn On, Rheem Furnace Blower Not Running, Rheem Furnace Flashing Light.

Safety first: anything beyond filters, batteries, and visual checks on gas-burning equipment should be handled by a licensed technician. Repeatedly resetting a locked-out unit can mask a dangerous fault. When in doubt, get a pro.

Parts & tools for this fix

As an Amazon Associate, fixme.vip earns from qualifying purchases. Prices and availability are on Amazon.

Frequently asked questions

Why does my Rheem furnace click but not start?

A click usually means a relay or the gas valve is being energized, but ignition fails. Common causes are a failing igniter, a relay or control board problem, a failed draft inducer motor, a weak transformer, or a safety switch stopping the sequence before the burners light.

Is the clicking sound dangerous?

The clicking itself is usually the control board relay or gas valve trying to cycle, which is not inherently dangerous. However, repeated failed ignition attempts should be diagnosed by a pro, since it can involve the gas valve and ignition system. If you smell gas at any point, do not reset the furnace or touch any switches. Leave the home and call your gas utility or 911 from outside.

Can I fix a clicking Rheem furnace myself?

You can safely check the filter, thermostat batteries, breaker, and that panels are seated, then try one reset by cycling power. Anything inside the cabinet, including relays, igniters, the inducer motor, wiring, and the gas valve, is technician work.

Does the furnace lock out after clicking?

Usually, yes, but lockout behavior and duration vary by control board. Many Rheem and Ruud integrated furnace controls use a timed soft lockout that automatically retries ignition after about an hour, while others behave differently. The board flashes a diagnostic code, usually visible through the window in the lower (blower) door, that identifies the fault. Repeated lockouts mean a technician needs to find the cause.

Different code on your furnace? Look it up — and if we haven't covered it yet, telling us is how it gets written next.