York · Heat Pump

York Heat Pump Not Cooling: Causes, Fixes & Costs

Last updated Oct 5, 2026 · By fixme.vip Editorial

York Heat Pump: Not cooling
Applies to: York split-system heat pumps, including the LX, Affinity and YZV variable-speed models, plus communicating systems using the Affinity Hx thermostat. Defrost board layout, fault-LED meanings and refrigerant type (R-410A vs R-454B) vary by model and year, so check the wiring diagram on the outdoor unit panel.
Typical repair cost: $0 DIY – $3,000+ if the compressor or reversing valve needs replacement — compare free local quotes

Get this fixed by a local pro

Free, no-obligation quotes from licensed HVAC technicians in your area. Compare up to 3 estimates before anyone visits.

Get free local quotes

York heat pump not cooling: what it means

“Not cooling” is a symptom, not a numbered fault code. Your York heat pump either won’t run in cooling mode or runs without bringing the indoor temperature down.

A heat pump cools by shifting its reversing valve into cooling position. On most York systems, the thermostat energizes the O terminal to do this. The compressor then pumps refrigerant to pull heat out of the house.

Cooling fails when any link in that chain breaks:

Some York units with a fault-LED defrost board, or variable-speed/communicating models such as systems using the Affinity Hx communicating thermostat, may show a stored fault code. One example is a high- or low-pressure switch lockout. LED meanings differ by board, so read the label inside the outdoor unit’s control panel cover. A technician can do this, or you can find it in the installation manual.

Pressure-switch lockouts on some York boards clear automatically after a delay. Others hold until power is cycled. Cycle power no more than once. If it locks out again, call a technician.

York heat pump not cooling: common causes, ranked by probability

  1. Thermostat setting or configuration. The thermostat may be set to Heat or Auto, or the setpoint may sit above room temperature. On a newly installed thermostat, the reversing-valve setting may be wrong. York normally uses O, energized in cooling. If it is set to B, the unit heats when you ask for cooling.
  2. Dirty air filter or blocked airflow. Restricted airflow can freeze the indoor coil, and cooling drops off sharply. Closed registers and blocked returns cause the same problem.
  3. Dirty or blocked outdoor coil. Cottonwood, grass clippings, leaves or nearby shrubs keep the unit from rejecting heat. Head pressure rises and the high-pressure switch may trip.
  4. Failed run capacitor or contactor in the outdoor unit. The outdoor fan or compressor won’t start, or the unit hums. This is one of the most common outdoor-unit failures on any brand. In field service calls, the capacitor is often the top hardware failure behind a no-cool complaint. It sits below causes 1–3 here only because those are simpler problems you can check yourself first.
  5. Low refrigerant from a leak. You may notice long run times, an iced suction line or poor temperature drop. Evaporator coil leaks from corrosion are common on older units of all brands. If a coil leak is found, check whether your coil is still under York’s registered parts warranty.
  6. Reversing valve stuck in heating position, or a failed solenoid coil. The outdoor unit runs, but the house gets warmer.
  7. Outdoor fan motor failure. The compressor runs but the fan doesn’t. High pressure builds until the unit trips.
  8. Pressure switch trip or control board fault. This shows on fault-LED boards. It can be triggered by any of causes 3–7, or by a failed switch or board.
  9. Compressor failure. This is the least likely cause and the most expensive. Signs include a locked rotor, an open winding or an internal overload that won’t reset.

How to fix York heat pump not cooling: safe checks first

Do not open the outdoor unit’s electrical panel. It holds high voltage, and capacitors stay charged even with the power off.

How a technician will diagnose it

A competent technician will typically work through these steps:

  1. Verify the thermostat call. They check for 24 V on Y and O at the outdoor unit and confirm the thermostat’s O/B configuration.
  2. Read the board. They check any fault LED or stored code on the defrost or control board, or pull the history on communicating York controls.
  3. Check power and start components. They measure line voltage at the contactor, inspect the contactor points and test the dual run capacitor with a meter against its µF rating.
  4. Check the fan and compressor. They confirm the outdoor fan motor runs and measure compressor amp draw and winding resistance.
  5. Measure the refrigerant system. They attach gauges or probes and record suction and liquid pressures, superheat and subcooling. These numbers are compared with York’s charging chart for the specific model and metering device (TXV or piston).
  6. Test the reversing valve. They check the temperatures on the valve’s lines and test the solenoid coil for voltage and resistance.
  7. Measure airflow and temperature split. They measure the supply and return temperature difference (about 15–20°F is typical) and static pressure. They also inspect the indoor coil for dirt or ice.
  8. Find leaks if the charge is low. They use an electronic detector, bubble solution or a nitrogen pressure test before recharging.

Be cautious of a quote that recommends a refrigerant top-off without measurements or any mention of finding the leak. Be equally cautious of a compressor replacement quote issued before the capacitor and contactor were tested.

Symptom, cause and what to do

SymptomLikely causeDIY actionTechnician job
Blows warm air, outdoor unit runningThermostat on Heat or wrong O/B setting; stuck reversing valveSet the thermostat to Cool; check the O/B setting in the thermostat installer menuTest the O signal and the reversing-valve solenoid; replace the valve or coil
Nothing runs, indoor or outdoorThermostat batteries, tripped breaker, float switchReplace batteries; reset the breaker once; clear the condensate drainCheck the transformer, low-voltage fuse and wiring
Indoor fan runs, outdoor unit silentOutdoor disconnect off, contactor, pressure lockoutCheck the disconnect and breaker; one power-cycle resetTest the contactor, capacitor, pressure switches and board
Outdoor unit hums but won’t startFailed capacitor or seized motor/compressorTurn the system off and don’t keep retryingReplace the capacitor; add a hard-start kit; test the compressor
Compressor runs, outdoor fan doesn’t spinFan capacitor or fan motorTurn the system offReplace the capacitor or fan motor
Ice on the indoor coil or suction lineDirty filter, low airflow, low refrigerantReplace the filter; run the fan only to thawCheck airflow; leak search and repair; recharge
Runs constantly, house only slightly coolerLow charge, dirty coils, undersized unit or extreme heatClean around the outdoor unit; replace the filterMeasure the charge; clean the coils; perform a load assessment
Short runs, then shuts offHigh-pressure trip from a dirty coil or fan failureClear debris; rinse the fins from outside with the power offDiagnose the pressure switch trip cause; clean the coil

York heat pump not cooling repair cost

These are typical US installed prices. They vary by region, refrigerant type and warranty status. York parts warranties are often 5–10 years when the unit is registered, but labor usually isn’t covered.

RepairTypical cost
Thermostat batteries, filter, clearing debris$0–$40 DIY
New heat pump thermostat$50–$250 DIY, $150–$450 installed
Service or diagnostic call$90–$250
Run capacitor replacement$150–$400
Contactor replacement$150–$350
Outdoor fan motor$350–$800
Coil cleaning (outdoor and/or indoor)$100–$400
Leak search$200–$600
Refrigerant recharge, R-410A$200–$700 depending on pounds needed
Refrigerant recharge, R-454B (newer units)Often higher than R-410A
Reversing valve solenoid coil$150–$400
Reversing valve replacement$900–$2,000
Pressure switch$150–$400
Defrost or control board$400–$1,200 (communicating and variable-speed boards run toward the top of the range)
Indoor evaporator coil replacement$1,200–$3,000
Compressor replacement$1,800–$3,500+

On an older system, a compressor or coil replacement often makes replacing the whole heat pump worth comparing. A new system typically runs $5,000–$12,000.

York Heat Pump Not Heating: Causes, Fixes & Costs covers heating-mode failures, defrost problems and the reversing valve from the heating side.

York Furnace Blower Not Running: Causes & Fixes applies when the indoor fan won’t run in cooling mode on a furnace-paired system.

York Furnace Leaking Water: Causes, Fixes & Costs covers condensate drain and float switch issues that can shut down cooling.

York Furnace Short Cycling: Causes, Diagnosis & Fixes covers thermostat and control cycling issues that overlap with cooling-side complaints.

Safety first: anything beyond filters, batteries, and visual checks on gas-burning equipment should be handled by a licensed technician. Repeatedly resetting a locked-out unit can mask a dangerous fault. When in doubt, get a pro.

Parts & tools for this fix

As an Amazon Associate, fixme.vip earns from qualifying purchases. Prices and availability are on Amazon.

Frequently asked questions

Why does my York heat pump blow warm air in cooling mode?

The most common reasons are a thermostat set to Heat or Auto, or a thermostat configured for the wrong reversing-valve type (O vs B). A stuck reversing valve, a failed outdoor capacitor or contactor, or low refrigerant can also cause it. A technician needs to diagnose the last three.

Can I add refrigerant to my York heat pump myself?

No. Handling refrigerant requires EPA Section 608 certification. Low refrigerant also means there is a leak. A technician should find and repair the leak before recharging. Topping off without a leak repair only postpones the problem.

My York heat pump runs, but the outdoor fan isn't spinning. What should I do?

Turn the system off at the thermostat right away so the compressor doesn't overheat. A stopped outdoor fan usually points to a failed run capacitor or fan motor. Both sit inside the outdoor cabinet, so they are technician repairs.

Does a York heat pump reset itself after a cooling fault?

Many York defrost and control boards add a short anti-short-cycle delay of several minutes before the compressor restarts. Some models lock out after repeated high- or low-pressure switch trips and need a power cycle to reset. Lockout behavior varies by board. Reset only once, and call a technician if it trips again.

Different code on your heat pump? Look it up — and if we haven't covered it yet, telling us is how it gets written next.